Acrobiosystems for English
icon_bulk_orderBulk inquiry/Quick order
0
There is no goods in the shopping cart !
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: Home > Kits > Spike S1 > RAS-T095

Anti-SARS-CoV-2 Antibody IgG Quantitative and Titer Detection Kit (Spike S1)

For research use only.

Order Now

IDComponentsSize
RAS095-C01Pre-coated SARS-CoV-2 Spike S1 Microplate1 plate
RAS095-C02Positive Control100 μL
RAS095-C03Negative Control100 μL
RAS095-C04Calibrator10.5 mL
RAS095-C05Calibrator20.5 mL
RAS095-C06Calibrator30.5 mL
RAS095-C07Calibrator40.5 mL
RAS095-C08Calibrator50.5 mL
RAS095-C09Calibrator60.5 mL
RAS095-C10HRP-Anti-Human IgG200 μL
RAS095-C1110xWashing Buffer50 mL
RAS095-C12Dilution Buffer50 mL
RAS095-C13Substrate Solution12 mL
RAS095-C14Stop Solution7 mL
  • Background
    The newly identified Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has posed a serious threat to human health. A rapid and effective Assay kit detecting the levels of anti-SARS-CoV-2 in human serum can facilitate research on characterization of antibodies produced in response to SARS-CoV-2 infection.
  • Application

    This kit is developed for quantitative or titer detection of Anti-SARS-CoV-2 Antibody IgG (Spike S1) in human serum. It is intended for research use only (RUO).

    It is for research use only.

  • Reconstitution
    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
  • Storage & Shipping
    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

    Shipping Statement

  • Assay Principles
    This assay kit employs a standard indirect-ELISA format, providing a rapid detection of anti-SARS-CoV-2 IgG in serum by SARS-CoV-2 Spike protein S1. The kit consists of High-bind Plate, Spike protein S1, an Positive Control, Negative Control, Calibrator, an HRP-Anti-Human IgG secondary antibody and Dilution buffer.

    Your experiment will include 4 simple steps:

    a) Add your sample and Calibrator to the plate. The samples are diluted by Dilution Buffer.

    b) Add a diluted Secondary antibody HRP-Anti-Human IgG to the plate. The Secondary antibody is diluted by Dilution Buffer.

    c) Wash the plate and add TMB or other colorimetric HRP substrate.

    d) Stop the substrate reaction by add diluted acid. Absorbance (OD) is calculate as the absorbance at 450 nm minus the absorbance at 630 nm to remove background prior to statistical analysis. The OD Value reflects the amount of antibody bound.

  • Clinical and Translational Updates

Comments (0)


ETD of in-stock products: 2 business days

Price(USD) : $780.00

Promotion & Exhibitions



Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message